How To Replace The Pelton Crane Delta XL8 Door Insulation Pad

Replacing The Door Insulation Pad Could Not Be Easier With These Simple Instructions Note: While these instructions are specific for replacing the Delta XL8 Insulation Pad, they are exactly the same...

View Article


Image may be NSFW.
Clik here to view.

Statim 2000 Autoclave Does Not Power Up

It can be very frustrating when you turn on your Statim 2000 Autoclave & nothing happens But, like all other autoclave troubleshooting, it’s just a matter of knowing where to start to find &...

View Article


Image may be NSFW.
Clik here to view.

OCR Autoclave Repair: The Case of the Mysterious Door Leak

Any time there is a leak around the door on the Pelton Crane OCR Autoclave, everyone automatically assumes it is due to a faulty door gasket And for the most part, they are usually right But what if...

View Article

Image may be NSFW.
Clik here to view.

Midmark M11 Autoclave Repair – Top 4 Problems & Fixes For Error Code C983

Pressure Leaks & Error Code C983 Pressure Leaks are the most common cause of the error code C983 on newer model Midmark M11 autoclaves (M11-020 thru -022 with Serial # prefixes RS, RT, RV &...

View Article

Image may be NSFW.
Clik here to view.

Statim 5000 Autoclave Repair: The Case of the Wet Instruments & the Noisy...

We got a call last week from a dentist who told us the Air Compressor on his Statim 5000 was making a loud noise. He also told us the instruments he was sterilizing were coming out wet Both of these...

View Article


Image may be NSFW.
Clik here to view.

Statim Error: Check Cassette 1

[et_pb_section][et_pb_row][et_pb_column type=”4_4″][et_pb_text]Statim 2000 Error Code: “CHECK CASSETTE #1” Note: “Check Cassette” Error Codes were used on the early model Statim Autoclaves, and when...

View Article

Hello, world.

Hello, world. First post!

View Article

Hello world!

Welcome to WordPress. This is your first post. Edit or delete it, then start writing!

View Article


Image may be NSFW.
Clik here to view.

The Case Of the Alien Midmark Vent Valve

Dr B’s Midmark M9 Autoclave stopped working and was giving her the C983 error code.  Not sure what to do, she called a company and received a repair estimate of more than $1500.00.  The estimate...

View Article


Image may be NSFW.
Clik here to view.

The Case of the Dead Statim Compressor (And How to Prevent It From Happening...

We got a call from Kevin M that the instruments he was sterilizing in his Statim 2000 Autoclave were coming out wet and there was water standing inside the cassette It was completing the cycle without...

View Article

Image may be NSFW.
Clik here to view.

The Case Of The Not So Hot Midmark Autoclave

We got a call from Jeremy this morning about his M11 autoclave not working. He told us he started by selecting the “pouch” cycle.  It filled with water and then advanced to the heat up stage like it is...

View Article

Image may be NSFW.
Clik here to view.

The Case of the Whistling Tuttnauer EZ9 Autoclave

We got a call from Donna telling us that her EZ9 had recently started whistling when she walked by.   (She was flattered at first, until she realized it was whistling at everybody) It had never done...

View Article